net.ihe.gazelle.assets.SearchCriteria : 14 assertions found for this search Review filtered assertions

Assertion

Applies to

Applied to
Not applied to

Coverage

Covered by
Not covered by
Id scheme
Assertion id
Status
Testable?
#Coverage
#Applies to
Comment
Predicate
Page
Tags
Last changed
Actions
RAD69RAD69-001reviewedTestable 2 2 extracts the XDSDocumentEntry.uniqueId and a repositoryUniqueId associated with the Imaging Document Source from the manifest (KOS) object retrieved previously via the Retrieve Document Set transaction187Section 4.69.4.1.28/26/19 5:33:50 PM by aeschlimann
RAD69RAD69-002reviewedTestable 1 3 The Request shall contain:+ repositoryUniqueId that identifies the Imaging Document Source from which the DICOM instance is to be retrieved.+ one or more documentUniqueIds that identify the documents within the Imaging Document Source.+ one or more DICOM transfer syntax UIDs that the Imaging Document Consumer is capable of processing. + Study Instance UID value that identifies the study containing the DICOM images/ objects to be retrieved. + Series Instance UID value that identifies the series containing the DICOM images/ objects to be retrieved. homeCommunityID, if the Retrieve Imaging Document Set request is to an Initiating Imaging Gateway.187Section 4.69.4.1.28/26/19 5:33:54 PM by aeschlimann
RAD69RAD69-008reviewedTestable 0 1 Shall use Async if IDS supports it. 189Section 4.69.4.35/10/19 9:48:41 AM by wbars
RAD69RAD69-010reviewedTestable 1 2 shall use the non-anonymous response EPR in the WS-Addressing replyTo header189Section 4.69.4.38/26/19 5:35:43 PM by aeschlimann
RAD69RAD69-011reviewedTestable 0 4 Shall use the Asynchronous Web Services Exchange method in the ITI TF-2x: Appendix V.5: Web Services for IHE Transactions,189Section 4.69.4.35/10/19 9:48:41 AM by wbars
RAD75RAD75-002reviewedTestable 1 1 The Responding Imaging Gateway shall determine the Imaging Document Source(s) which hold the imaging documents requested and initiate a RAD-69 transaction to those Imaging Document Sources. 202Section 4.75.4.1.39/17/19 11:48:37 AM by aeschlimann
RAD75RAD75-003reviewedTestable 0 1 If more than one Imaging Document Source is contacted, the Responding Gateway shall consolidate the results from the multiple sources into one response. If both successes and failures are received, the Responding Gateway may choose to use PartialSuccess status to reflect both failure and success. The Responding Gateway may alternatively choose to suppress the failures and report only successes202Section 4.75.4.1.35/2/19 5:21:44 PM by wbars
RAD75RAD75-004reviewedTestable 1 1 Every RegistryError element returned in the response shall have the location attribute set to the homeCommunityId of the Responding Imaging Gateway202Section 4.75.4.1.39/17/19 11:48:48 AM by aeschlimann
RAD75RAD75-006reviewedTestable 0 2 The Initiating and Responding Imaging Gateways shall support the Asynchronous Web Services Methods in the ITI TF-2x: Appendix V.5: Web Services for IHE Transactions203Section 4.75.4.25/2/19 5:22:49 PM by wbars
XCAIXCAI-005reviewedTestable 1 1 Responding Imaging Gateway must support Retrieve Imaging Document Set [RAD-69] transaction.250Section 29.18/26/19 3:21:26 PM by aeschlimann
XCAIXCAI-006reviewedTestable 1 1 Responding Imaging Gateway must support Cross Gateway Retrieve Imaging Document Set [RAD-75] transaction.250Section 29.18/26/19 3:21:30 PM by aeschlimann
XCAIXCAI-007reviewedTestable 0 1 RAD TF-1 does not show an option for RIG support of Async on RAD-69, but I (Ralph) think that is because it is not optional. RAD TF-3 4.69.4.3 states: A Responding Imaging Gateway shall use the Asynchronous Web Services Exchange method if the Image Document Source supports the Asynchronous Web Services Option. Responding Imaging Gateway must support the use of Asynchronous Web Services Methods for RAD-75. The documentation does not show an option for async support for RAD-69.252Section 29.1.18/26/19 5:25:26 PM by wbars
XCAIXCAI-022reviewedTestable 0 1 Initiate one or more Retrieve Document Set transaction [RAD-69] to the Imaging Document Source identified by the Retrieve Location UID(s) within the request and consolidate the responses in repsonse to RAD-75253Section 29.3.28/26/19 3:21:09 PM by aeschlimann
XCAIXCAI-026reviewedTestable 1 1 Responding Imaging Gateway shall return either zero documents with no further information or XDSUnknownPatientId in response to queries of unknown patient identifiers, depending on local policy. This applies to patient identifiers that are properly formatted or improperly formatted.257Section 29.4.28/26/19 3:20:48 PM by aeschlimann