CH-XDSI | CH-XDSI-001 | to be reviewed | Testable |
1
|
0
| | When the Imaging Document Source provides KOS objects, the purpose of use of the X-User Assertion SHALL be equal to DICOM_AUTO. | 8 | Section 1.3.a | 9/5/23 12:08:07 PM by vhofman |
|
CH-XDSI | CH-XDSI-002 | to be reviewed | Testable |
1
|
0
| | When the Imaging Document Source provides KOS objects, the DocumentEntry.formatCode SHALL be equal to the coded value of DICOM Manifest (1.2.840.10008.5.1.4.1.1.88.59^^1.2.840.10008.2.6.1). | 8 | Section 1.3.b | 9/5/23 11:55:03 AM by vhofman |
|
CH-XDSI | CH-XDSI-003 | to be reviewed | Testable |
1
|
0
| | When the Imaging Document Source provides KOS objects, the DocumentEntry.mimeType SHALL be equal to application/dicom. | 8 | Section 1.3.c | 9/5/23 11:55:05 AM by vhofman |
|
CH-XDSI | CH-XDSI-004 | to be reviewed | Testable |
1
|
0
| | When the Imaging Document Source provides KOS objects, the StudyInstanceUID referenced in the KOS object SHALL be conveyed in the DocumentEntry.referenceIdList (urn:ihe:iti:xds:2013:referenceIdList). | 8 | Section 1.3.d | 9/5/23 11:55:06 AM by vhofman |
|
RAD68 | RAD68-003 | reviewed | Testable |
1
|
1
| | The Imaging Document Source creates a manifest that describes and collects references to DICOM SOP instances that are intended for sharing. The manifest, a Key Object Selection (KOS) Document Instance, is the actual document provided to the Document Repository and registered at the Document Registry. | 472 | Section 4.68.4.1.2.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-004 | reviewed | Testable |
1
|
1
| | The structure of the Request message between the XDS Document Source and the XDS Document Repository is an MTOM/ XOP formatted message. | 473 | Section 4.68.4.1.2.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-005 | reviewed | Testable |
1
|
1
| | The KOS Document Instance is encoded in the Request message as a DICOM Part 10 File format having a MIME type of “application/dicom”. | 473 | Section 4.68.4.1.2.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-006 | reviewed | Testable |
1
|
1
| | The Imaging Document Source shall ensure that the DICOM SOP Instances referenced from within the manifest are available to be retrieved.If the XDS-I Imaging Document Source makes one or more SOP Instances unavailable that are referenced in a published manifest, then it shall submit a new manifest as a replacement for the published manifest already in the XDS Document Repository and XDS Document Registry (see IHE ITI TF-3:4.2.2.2 Document Relationships).The new manifest shall have the updated list of DICOM SOP Instances with the unavailable instances removed. | 473 | Section 4.68.4.1.2.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-008 | reviewed | Testable |
1
|
1
| | The references to the DICOM SOP Instances shall be included in the Current Requested Procedure Evidence Sequence (0040,A375) attribute of the KOS Manifest Document. | 473 | Section 4.68.4.1.2.1.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-009 | reviewed | Testable |
1
|
1
| | The Imaging Document Source shall support these attributes in Current Requested Procedure Evidence Sequence (0040,A375), which are represented in the Hierarchical SOP Instance Reference Macro: Study Instance UID (0020,000D) & Referenced Series Sequence (0008,1115) & Series Instance UID (0020,000E) & Referenced SOP Sequence (0008,1199) & Referenced SOP Class UID (0008,1150) & Referenced SOP Instance UID (0008,1155) | 473 | Section 4.68.4.1.2.1.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-010 | reviewed | Testable |
1
|
1
| | The Imaging Document Source shall support these attributes in Current Requested Procedure Evidence Sequence (0040,A375), which are represented in the Hierarchical SOP Instance Reference Macro, using its own identification:Retrieve AE Title (0008,0054) & Retrieve Location UID (0040,E011) | 473 | Section 4.68.4.1.2.1.1 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-012 | reviewed | Testable |
1
|
1
| Imaging Document Source set to NONE | The Imaging Document Source shall support shared reports in at least one of the following formats: CDA Imaging Report with Structured Headings, CDA Wrapped Text Report or PDF Report. | 474 | Section 4.68.4.1.2.2 | 11/22/23 2:50:41 PM by vhofman |
|
RAD68 | RAD68-016 | reviewed | Testable |
1
|
1
| Imaging Document Source set to NONE | The Imaging Document Source is required to ensure that image references are valid links. | 475 | Section 4.68.4.1.2.2 | 11/22/23 4:36:49 PM by vhofman |
|
RAD68 | RAD68-017 | reviewed | Testable |
1
|
1
| | The Provide and Register Imaging Document Set MTOM/XOP Request message shall include the metadata attributes that will be forwarded by the Document Repository to the XDS Document Registry using the Register Document Set-b [ITI-42] transaction. | 475 | Section 4.68.4.1.2.3 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-018 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: creationTimeshall record the date and time at which the clinical content conveyed in the shared document is created. If the published document is a DICOM object or is transformed from a DICOM information object, this attribute value should be taken from the tags Instance Creation Date (0008,0012) and Instance Creation Time (0008,0013) of the DICOM object. | 476 | Section 4.68.4.1.2.3.2 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-024 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: formatCodeShall use urn:ihe:rad:PDF for a PDF Report. | 477 | Section 4.68.4.1.2.3.2 | 11/22/23 4:43:52 PM by vhofman |
|
RAD68 | RAD68-026 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: mimeType shall be application/dicom for a DICOM Manifest document | 477 | Section 4.68.4.1.2.3.2 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-028 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: mimeTypeShall be application/pdf for a PDF Report | 477 | Section 4.68.4.1.2.3.2 | 11/22/23 4:47:09 PM by vhofman |
|
RAD68 | RAD68-032 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: serviceStartTime shall be populated by the Imaging Document Source for a date and time that indicates the imaging service start time. | 478 | Section 4.68.4.1.2.3.2 | 2/1/24 9:55:02 AM by alegrand |
|
RAD68 | RAD68-033 | reviewed | Testable |
1
|
1
| | XDSDocumentEntry Attribute: sourcePatientInfo, This attribute allows multiple values for different pieces of patient demographics. | 478 | Section 4.68.4.1.2.3.2 | 11/22/23 4:49:51 PM by vhofman |
|