View Transaction

View Transaction Information

Id: 170

Keyword: PCD-3

Name: Communicate Infusion Order

Description: This transaction contains the information from the Infusion Order Placer, such as caregiver, patient, and pump identification, medication, volume, and rate, for the infusion being programmed.

TF Reference:

Status: Final Text

Referenced standards :

If there is no referenced standard the transaction will not appear in the inbound/outbound configurations supported by a system

Document Section :

None

Id
Keyword
Name
Description
Action
84 PIV2009 DEPRECATED: 2009 Point-of-Care Infusion Verification This profile entry represents the structure of actors and options in the PIV profile as published in 2009 and tested at NA2010. The documentation was updated in 2010, and the new profile entry, PIV, represents the updated structure.
204 T73 HITSP Aggregate Device Information Communication US HITSP: T73. The Aggregate Device Information Communication Transaction allows a system serving as a device intermediary such as a home hub, a cell phone, a set top box, or a monitoring station to which one or more monitoring devices are connected to forward a set of observations through a local or remote connection to a remote monitoring management system where these device captured observations will be reviewed by a person managing the care of the patient under remote monitoring
229 PIV Point-of-Care Infusion Verification The Point-of-Care Infusion Verification profile supports the electronic transfer of infusion parameters from a Barcode Point of Care (BPOC) system, also known as a Bar Code Medication Administration (BCMA) system, to an infusion pump. This capability will reduce errors by eliminating keystroke errors and by increasing the use of automatic dosage checking facilitated by onboard drug libraries. In addition to the reduction of medication administration errors, this integration may also increase caregiver productivity and provide more contextual information regarding infusion data.
Id
Keyword
Name
Description
Action
77DEV_OBS_REPORTERDevice Observation ReporterThe Device Observation Reporter (DOR) actor receives data from PCDs, including those based on proprietary formats, and maps the received data to transactions providing consistent syntax and semantics.
79DEV_OBS_CONSUMERDevice Observation ConsumerThe actor responsible for receiving PCD data from the Device Observation Reporter, the Device Observation Filter, or both.
117IOPInfusion Order ProgrammerThe Infusion Order Programmer (IOP) actor sends the information comprising an order to the Infusion Order Consumer (IOC). The mechanism by which the IOP obtains the order information is outside the scope of this profile.
118IOCInfusion Order ConsumerThe Infusion Order Consumer (IOC) actor receives the order information from the IOP actor and in turn programs the pump. The mechanism by which the IOC programs the pump with the received information is outside the scope of this profile.