CH-XCPD-001 | For the EPR only the Shared/National Patient Identifier Query mode MUST be used. Other modes as defined in this transaction (see also IHE ITI TF-2b, chapter 3.55.1) MUST NOT be used (see Section 1.10.1 Modes and Options) |
CH-XCPD-002 | The Health Data Locator and Revoke Option of the Patient Location Query transaction [ITI-56] MUST NOT be used (see Section 1.10.1 Modes and Options) |
CH-XCPD-003 | The Initiating Gateway may specify a duration value in the SOAP Header element of the request. This value suggests to the Responding Gateway a length of time that the Initiating Gateway recommends caching any correlation resulting from the interaction. This values MUST NOT exceed 3 days. See also IHE ITI TF-2b, chapter 3.55.4.1 (see Section 1.10.2 Cross Gateway Patient Discovery Request) |
CH-XCPD-004 | LivingSubjectId Parameter is the only required query Parameter. The following parameters of IHE ITI TF-2b, chapter 3.55.4.1.2.1 MAY be used (see Section 1.10.2.1 Major Components of the Patient Registry Query by Demographics) |
CH-XCPD-005 | The LivingSubjectId Parameter MUST contain the EPR-PID (see Section 1.10.2.1 Major Components of the Patient Registry Query by Demographics) |
CH-XCPD-006 | Reverse Cross-Gateway Queries MUST NOT be used (see IHE ITI TF-2b, chapter 3.55.4.1.2.4) (see Section 1.10.2.1 Major Components of the Patient Registry Query by Demographics) |
CH-XCPD-007 | In the Patient parameter, The MPI-PID MUST be returned if there is a match from the EPR-SPID (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-008 | In the "Patient" parameter, the "confidentialityCode" MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-009 | In the "Patient" parameter, the veryImportantPersonCode MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-010 | In the "Person" parameter, either "Person.name" or "Patient.id" must be non-null (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-011 | In the "Person" parameter, the "telecom" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-014 | In the "Person" parameter, the "deceasedInd" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-015 | In the "Person" parameter, the "deceasedTime" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-016 | In the "Person" parameter, the "multipleBirthInd" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-017 | In the "Person" parameter, the "multipleBirthOrderNumber" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-018 | In the "Person" parameter, the "addr" field MUST NOT be used MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-019 | In the "Person" parameter, the "maritalStatusCodeCode" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-020 | In the "Person" parameter, the "religiousAffiliationCode" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-021 | In the "Person" parameter, the "raceCode" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |
CH-XCPD-022 | In the "Person" parameter, the "ethnicGroupCode" field MUST NOT be used (see Table 13: Message Information Model for Patient Registry Find Candidates) |