Actor : Device Observation Filter

Actor Details Last changed 4/17/08 12:09:39 PM by Unknown

78
DEV_OBS_FILTER
Device Observation Filter
The Device Observation Filter (DOF) actor is responsible for providing PCD data filtering services based on publish/subscribe predicates negotiated with client applications implementing the Device Observation Consumer.
Id
Keyword
Name
Description
Status
Action
276 DEC Device Enterprise Communication The Device Enterprise Communication Profile supports communication of vendor independent, multi-modality Patient Care Devices data to Enterprise Applications using consistent semantics. It accomplishes this by mapping PCD data from proprietary syntax and semantics into a single syntactic and semantic representation for communication to the enterprise. The PCD data is time stamped with a consistent enterprise time. Options are provided to allow applications to filter particular PCD data of interest Final Text
27 DEC2009 DEPRECATED: 2009 Device Enterprise Communication This entry represents the DEC profile as it was documented in the PCD TF in 2009. In 2010, the PDC actor was removed from DEC and brought in through grouping. The new profile actor/option structure is entered under the DEC profile entry in gazelle. Deprecated
230 DEC2010 DEPRECATED: 2010 Device Enterprise Communication This entry represents how the DEC profile was documented in 2010. In 2011, the DOF actor was removed, the PCD-02 transaction was removed, and all options were removed Deprecated
84 PIV2009 DEPRECATED: 2009 Point-of-Care Infusion Verification This profile entry represents the structure of actors and options in the PIV profile as published in 2009 and tested at NA2010. The documentation was updated in 2010, and the new profile entry, PIV, represents the updated structure. Deprecated
Id
Keyword
Name
Description
TF Reference
Status
Specifications
Action
117 PCD-1 Communicate PCD Data Transmit PCD data to enterprise clients from a Device Observation Reporter or Observation Filter and Receive PCD data by a Device Observation Consumer. Final Text
118 PCD-2 Subscribe to PCD Data Defines predicate for communication of PCD data from DOF to a Device Observation Consumer. Trial Implementation
Assertion Id
Description
DEC-Vol1-001 Each actor implementing this Patient Care Device (PCD) profile shall be grouped with the IT Infrastructure Consistent Time profile Time Client Actor for the purpose of consistent time-stamping of messages and data
DEC-Vol2-001 The Communicate PCD Data [PCD-01] transaction references the following chapters from the HL7 Version 2.6 standard: Chapter 7 Observation Reporting
DEC-Vol2-002 The Communicate PCD Data [PCD-01] transaction references the IEEE 11073-10201 Domain Information Model standard
DEC-Vol2-003 The Communicate PCD Data [PCD-01] transaction references the IEEE 11073-10101a Nomenclature standard
DEC-Vol2-004 The static definition for the PCD-01 Communicate PCD Data message is defined in the unnamed table in this section of the doument
DEC-Vol2-005 The PCD-01 message structure differs from the basic HL7 version 2.6 by allowing for the appearance of PRT segments, a segment new in HL7 version 2.7, in certain locations.
DEC-Vol2-009 Device to Enterprise Communications PCD-01 Communicate PCD Data message (also used for observations in response to a PCD-02 PCD Data Query) shall contain in MSH-21 Message Profile Identifier the value 1.3.6.1.4.1.19376.1.6.1.1.1
DEC-Vol2-010 For PCD-01 messages the ORC segment use is X, i.e. not sent.
PCD-Vol2-001 OBX-3 shall be expressed as an HL7 Coded Element With Exceptions (CWE) data type
PCD-Vol2-003 Ordinal numbers in OBX-4 are not normative for a given parameter and may vary between implementations. They shall be unique within a given containment, however, numbers may change between messages.
PCD-Vol2-004 Source for nomenclature codes is IEEE 11073-10101 current version. Additional codes not yet standardized are contained in the RTMMS
PCD-Vol2-005 Periodic versus aperiodic data shall be distinguished by the IEEE 11073 Metric Access code in OBX-17
PCD-Vol2-006 The value in MSH-2 Encoding Characters shall be ^~\&
PCD-Vol2-007 MSH-3 Sending Application shall uniquely identify the software application implementing the actor sending the message
PCD-Vol2-008 If MSH-4 Sending Facility is populated, the first component shall identify the organizational entity responsible for sending the message, the second component if present shall identify the Universal ID of the organizational entity responsible for the sender of the message, the third component if present shall identify the Universal ID Type
PCD-Vol2-009 If MSH-5 Receiving Application is populated, the first component shall identify the organizational entity responsible for receiving the message, the second component if present shall identify the Universal ID of the organizational entity responsible for the sender of the message, the third component if present shall identify the Universal ID Type.
PCD-Vol2-010 If MSH-6 Receiving Facility is populated, the first component shall identify the organizational entity responsible for the receiving facility, the second component if present shall identify the Universal ID of the organizational entity responsible for the sender of the message, the third component if present shall identify the Universal ID Type
PCD-Vol2-011 In MSH-7 Date/Time of Message time zone shall be included in the field content
PCD-Vol2-012 In field MSH-11 Processing ID, the first component shall be present and be a value based upon HL7 Table 0103. The second component if present shall be a value based upon HL7 Table 0207.
PCD-Vol2-013 Field MSH-12 Version ID shall contain 2.6