Assertion

AssertionId
XDSI-016 Testable
predicate
When the Imaging Document Consumer retrieves a manifest from the Document Repository, it is expected to decode the Key Object Selection Document Instance in order to find the references to DICOM objects. The Imaging Document Consumer is also expected to retrieve the referenced DICOM objects using DICOM retrieve or WADO.
Prescription level
Mandatory / Required / Shall
Page
193
Section
18.4.1
Status
reviewed
Last changed
2/1/24 9:55:02 AM by alegrand
Comment

Applies to

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE Radiology (RAD) Technical Framework Volume 106/15/2023