Assertion

AssertionId
RAD68-006 Testable
predicate
The Imaging Document Source shall ensure that the DICOM SOP Instances referenced from within the manifest are available to be retrieved.If the XDS-I Imaging Document Source makes one or more SOP Instances unavailable that are referenced in a published manifest, then it shall submit a new manifest as a replacement for the published manifest already in the XDS Document Repository and XDS Document Registry (see IHE ITI TF-3:4.2.2.2 Document Relationships).The new manifest shall have the updated list of DICOM SOP Instances with the unavailable instances removed.
Prescription level
Mandatory / Required / Shall
Page
473
Section
4.68.4.1.2.1
Status
reviewed
Last changed
2/1/24 9:55:02 AM by alegrand
Comment

Applies to

Audit Messages

Integration Profiles

Transactions

Standards

Covered by

Test Steps

Rules

MBV

Covered by (Deprecated)

Tests

Test Steps

Rules

Document name
Provenance
Revision
Action
IHE Radiology (RAD) Technical Framework Volume 206/15/2023