XDSIXDSI-004reviewedNot testable 0 5 XDS and XDS-I.b do not address transactions for the management or configuration of an XDS Affinity Domain. For example, the configuration of network addresses or the definition of what type of clinical information is to be shared is specifically left up to the policies established by the XDS Affinity Domain.177Section 182/1/24 9:55:02 AM by alegrand
XDSIXDSI-005reviewedNot testable 0 5 XDS and XDS-I.b do not specifically address the patient information reconciliation process necessary between the XDS Affinity Domain and any other local patient identity domains that Document Sources and Document Consumers may be members of. For a discussion of some of these issues see RAD TF-1: Appendix G.177Section 182/1/24 9:55:02 AM by alegrand
XDSIXDSI-006reviewedNot testable 0 5 XDS and XDS-I.b do not directly address the rendering and display of the documents retrieved by the Document and Imaging Document Consumers. Users wishing to achieve a well-defined level of display/ rendering capability simply need to request systems that combine the XDS-I.b Imaging Document Consumer Actor with an Image Display Actor from the appropriate Profile (e.g., Mammography Image, NM Image, Basic Image Review, etc.).177Section 182/1/24 9:55:02 AM by alegrand
XDSIXDSI-008reviewedTestable 1 1 The Imaging Document Consumer Actor shall support retrieve operations using at least one of the following transactions+ [RAD-16] Retrieve Images+ [RAD-17] Retrieve Reports+ [RAD-45] Retrieve Evidence Documents+ [RAD-55] WADO Retrieve+ [RAD-69] Retrieve Imaging Document Set178Section 18.12/1/24 9:55:02 AM by alegrand
XDSIXDSI-016reviewedTestable 1 1 When the Imaging Document Consumer retrieves a manifest from the Document Repository, it is expected to decode the Key Object Selection Document Instance in order to find the references to DICOM objects. The Imaging Document Consumer is also expected to retrieve the referenced DICOM objects using DICOM retrieve or WADO.193Section 18.4.12/1/24 9:55:02 AM by alegrand
XDSIXDSI-017reviewedTestable 1 1 The Imaging Document Consumer "should not make any assumptions about whether one or more studies are referenced within the Key Object Selection Document."193Section 18.4.12/1/24 9:55:02 AM by alegrand
XDSIXDSI-018reviewedTestable 0 5 Read Appendix G for Patient Information Reconciliation considerations. Appendix G contains suggestions but no requirements.193Section 18.52/1/24 9:55:02 AM by alegrand
XDSIXDSI-019reviewedTestable 4 5 All XDS-I.b actors shall be grouped with either a Secure Node or Secure Application Actor from the ATNA Profile.193Section 18.62/1/24 9:55:02 AM by alegrand
XDSIXDSI-020reviewedTestable 1 5 All XDS-I.b actors ... shall ... support the Radiology Audit Trail Option193Section 18.62/1/24 9:55:02 AM by alegrand
XDSIXDSI-021reviewedNot testable 0 5 Read Appendix H for other security considerations. Appendix H contains suggestions but no requirements193Section 18.62/1/24 9:55:02 AM by alegrand